Installing The System Software Using The Sst; Execution Of Auto Adjust Gradation - Canon imageRUNNER ADVANCE C5255 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

9) Install the Option HDD (1TB).
• 2 Screws (The screw removed in step 8).)
CAUTION:
Be sure to prevent the gasket from coming off when installing.
x2
10)
Install the HDD Unit to the host machine. (2 Screws)
11)
Install the Signal Cable and the Power Cable to the Option HDD.
12)
Close the HDD Lid. (1 Screw)
13)
Close the Right Rear Cover 1.
14)
Close the Right Lower Cover.
15)
Close the Right Upper Cover.
16)
Connect the power plug of the host machine to the power outlet.

Installing the System Software Using the SST

The system data stored on the HDD and used to control the host machine will be lost when
the machine is first started up after installing this product.
It is important to install the system software used to control the host machine so that the
machine may start up properly after installation of this product.
Details follow.
9
Installation > [TYPE-1] > Execution of Auto Adjust Gradation
1. Requirements
1) PC
Service support tool in the version that supports this host machine must be installed.
2) Cross Ethernet Cable
2. Preparing for the Installation of the System Software of Host machine
1) If both PC and the machine are on, turn them off.
2) Connect the PC and the machine using an Ethernet cable.
3) Turn on the PC.
4) Start up the machine in download mode (safe mode).
3. Selecting the System Software
1) Set the CD containing the latest system software in the PC on which the SST is used.
2) Start up the SST.
3) Click Register Firmware.
4) Select the drive in which the System Software CD has been set, and click search.
5) Click REGISTER.
6) Click OK.
4. Downloading the System Software
F-9-450
1) Click "Start Assist Mode" and click "Initialize" according to the instruction on the screen.
2) When initialization is completed, the machine is automatically restarted and it enters
download mode.
3) Select the version to be downloaded and click "Start".
4) When download is completed, the machine is automatically restarted.
5) When writing of the firmware is completed, the machine is automatically restarted.
6) Perform upgrading according to the instruction on the screen. When it is completed, it is
automatically restarted.
7) Terminate the SST.
8) Check the version of the downloaded firmware in service mode.

Execution of Auto Adjust Gradation

When this product is installed, the machine initializes its HDD, resetting the data used for
auto gradation adjustment.
Therefore be sure to execute auto gradation adjustment (full adjust) after installing this kit.
9
Installation > [TYPE-1] > Execution of Auto Adjust Gradation
9-176
9-176