Embedded RDS Troubleshooting

No.1
Symptom: A communication test (COM-TEST) results NG!
Cause: Initial settings or network conditions is incomplete.
Remedy 1: Check and take actions mentioned below.
1) Check network connections
Is the status indicator LED for the HUB port to which this machine is connected ON?
YES: Proceed to Step 2).
NO: Check that the network cable is properly connected.
2) Confirm loop back address (* In case of IPv4 )
Select [Settings/Registration (User Mode)] > [Preferences] > [Network] > [TCP/IP Settings]
> [IPv4 Settings] > [PING Command], enter "127.0.0.1", and touch the [Start] button.
Does the screen display "Response from the host."? (See the next figure.)
YES: Proceed to Step 3).
NO: There is a possibility that this machine's network settings are wrong. Check the
details of the IPv4 settings once more.
6
Troubleshooting > Embedded RDS Troubleshooting
F-6-202
6
Troubleshooting > Embedded RDS Troubleshooting
3) Confirmation from another PC connected to same network.
Request the user to ping this machine from a PC connected to same network.
Does this machine respond?
YES: Proceed to Step 4).
NO: Confirm the details of this machine's IP address and subnet mask settings.
4) Confirm DNS connection
(a) Select [Settings/Registration (User Mode)] > [Preferences] > [Network] > [TCP/IP
Settings] > [DNS Settings] > [DNS Server Address Settings], write down the primary
and secondary addresses of the DNS server, and touch the [Cancel] button.