Removing the Recycle Toner Bottle

■ Preparations
1) Open the Front Cover.
■ Procedure
1) Release the Recycle Toner Bottle Lock Lever.
2) Remove the Recycle Toner Bottle.
CAUTION:
Do not tilt the Recycle Toner Bottle.
(Because it may cause misdetection on the Full Detection Sensor.)
4
Parts Replacement and Cleaning > Image Formation System > Pulling Out the Process Unit > Procedure
F-4-181
F-4-182

Pulling Out the Process Unit

■ Preparations
1) Open the Front Cover, Right Lower Cover and Right Upper Cover.(Refer to page 4-104)
2) Remove the ITB Cover.(Refer to page 4-104)
■ Procedure
1) Make sure that the arrow of ITB Sub Pressure Release Lever is aligned with the triangle
mark of the plate.
(If it is not aligned, align the arrow of lever with the triangle mark of plate.)
Triangle mark
ITB sub pressure
release lever
2) Turn the ITB Pressure Release Lever in the right direction and release the pressure.
CAUTION:
When releasing the pressure of ITB Pressure Release Lever, make sure that the
protrusion of grip is aligned with the triangle mark of plate.
ITB pressure release lever
4-131
Triangle mark
ITB sub pressure
release lever
F-4-184
4-131