Canon imageRUNNER ADVANCE C5255 Series Service Manual page 783

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E747 850F
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 851C
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 851D
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 851F
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 951A
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
E
Detailed
Occurance
Items
code
code
area
E747 951B
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 9C00
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 9F00
00
Title
Detection shows that Sub Board O failed to be installed
Description Detection shows that Sub Board O failed to be installed
Remedy
Check contact of the Sub Board O and the cable, or
replace
-> Replace the Main Controller PCB 2
E747 BF00
00
Title
Detection shows that Sub Board O failed to be installed
Description Detection shows that Sub Board O failed to be installed
Remedy
Check contact of the Sub Board O and the cable, or
replace -> Replace the Main Controller PCB 2
E747 C000
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
E747 C519
00
Title
Error in Main Controller PCB2
Description Error in Main Controller PCB2
Remedy
1. Check contact of ScanI/F cable. Check contact of the
Bypass PCB or Open I/F PCB. Check contact of SDRAM
at Main Controller PCB2.
2. Replace the Bypass PCB or Open I/F PCB
3. Replace the SDRAM at Main Controller PCB2
4. Replace the Main Controller PCB2
5. Replace the HDD (replace the new encryption board)
7-92
Description
7-92

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents