4
Parts Replacement and Cleaning > Image Formation System > Removing the Secondary Transfer Inner Roller > Actions after Replacement
● If not, execute the following adjustment.
1) Open the ITB Cover.(Refer to page 4-104)
2) Remove the ITB Motor [1].
• 4 Screws [3]
• 1 Connector [2]
[3]
x4
[3]
3) Put markings as shown in the figure below to use as the reference when correcting the
position.
4
Parts Replacement and Cleaning > Image Formation System > Removing the Secondary Transfer Inner Roller > Actions after Replacement
When the values are above 350
Move the ITB Motor Support Plate up.
Moving it by 1 mm changes the values of ITB-POS and ITB-POS2 by approx. 200.
After adjustment, check that the values of COPIER>DISPLAY>MISC>ITB-POS and ITB-
POS2 are within the range from -350 to 350.
[1]
[2]
When the values are below -350
F-4-166
Move the ITB Motor Support Plate down.
Moving it by 1 mm changes the values of ITB-POS and ITB-POS2 by approx. 200.
After adjustment, check that the values of COPIER>DISPLAY>MISC>ITB-POS and ITB-
POS2 are within the range from -350 to 350.
Mark
Mark
F-4-167
4-125
Loosen
F-4-168
Loosen
F-4-169
4-125