Canon imageRUNNER ADVANCE C5255 Series Service Manual page 1014

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > OPTION > USER
NW-SCAN
Setting of network scan function usage
Lv.2 Details
To set whether to allow use of network scan function.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Do not change this mode in Japan.
- For PS/PCL machines for overseas (outside Japan), fix the setting
value as "1: Enabled". For others, permit the use.
Display/adj/set range
0 to1
0: Disabled, 1: Enabled
Default value
1
JOB-INVL
Job intvl setting at interruption copy
Lv.2 Details
To set output interval between jobs at the time of interruption copy.
Sorting is difficult after interruption copy because of the continuous
output of the next job. Paper interval becomes longer when starting
pickup for the next job after the last sheet of the previous job is
delivered.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2
0: Continuous output of the interruption copy and the next job
1: Starting pickup for the next job after the interruption copy is delivered
all.
2: Starting pickup for the next job after the previous job is delivered all.
(For all jobs)
Default value
0
LGSW-DSP
ON/OFF of "Log display ON/OFF setting"
Lv.2 Details
[Not used] To set whether to display "Management Settings> Device
Management> Display Log" in user mode.
When "1: ON" is set, "Display Log" is displayed in the "Device
Management" screen. When ON is set, the logs of each job are
displayed in "System Status."
When "0: OFF" is set, "Display Log" is not displayed in the "Device
Management" screen, and the logs of each job are not displayed either.
Display/adj/set range
0 to 1
0: OFF, 1: ON
TAB-ROT
Set of landscape img rotn at PDL:tab ppr
Lv.1 Details
To set whether to rotate landscape image by 180 degrees when PDL
print is made on tab paper.
When "1: Rotated" is set, image is rotated.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Not rotated, 1: Rotated
Default value
0
8
Service Mode > COPIER > OPTION > USER
8
Service Mode > COPIER > OPTION > USER
COPIER > OPTION > USER
PR-PSESW
Display/hide of output pause button
Lv.1 Details
To set whether to display or hide [Pause Printing] button on the system
status/stop screen.
Use case
- Upon user's request
- When promptly stopping the print job in operation or under reservation
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
0
IDPRN-SW
Charge target job set of dept mngm cntr
Lv.1 Details
To set the job type that advances the department management counter.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0:
PRINT category: Inbox Print, Report Print, Send Local Print, PDL Print
COPY category: COPY
1:
PRINT category: Report Print, Send Local Print, PDL Print
COPY category: COPY, Inbox Print
Default value
0
P-CRG-LF
Set operation at end of Dev Ass'y life
Lv.2 Details
To set the operation at the time when the Developing Assembly reaches
the end of its life.
When 1 is set, the Developing Assembly that has reached the end of its
life cannot be used.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Not stopped, 1: Stopped
Default value
0
CPRT-DSP
ON/OFF of [Print Charge Log] button
Lv.1 Details
To set whether to display the [Print Charge Log] button to print the
charge logs on the charge log screen in user mode.
When "1: ON" is set, the button is displayed in Management Settings>
Charge Management> Charge Log Screen.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0