Canon imageRUNNER ADVANCE C5255 Series Service Manual page 872

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

COPIER > DISPLAY > HT-C
TGT-C-C3
ARCDAT scrn C C-color target VL(1/3 SPD)
Lv.2 Details
To display the C-patch target value of screen C in ARCDAT control at
1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
TGT-C-K3
ARCDAT scrn C Bk-clr target VL(1/3 SPD)
Lv.2 Details
To display the Bk-patch target value of screen C in ARCDAT control
at 1/3 speed.
Use case
When checking ARCDAT control operation
Display/adj/set range
0 to 1023
Appropriate target value 0 to 700
SUM-A-Y2
ARCDAT scrnA Y-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display Y-patch control difference of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-M2
ARCDAT scrnA M-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display M-patch control difference of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-A-C2
ARCDAT scrnA C-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display C-patch control difference of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER > DISPLAY > HT-C
SUM-A-K2
ARCDAT scrnA Bk-clr ctrl differ(1/2 SPD)
Lv.2 Details
To display Bk-patch control difference of screen A in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-Y2
ARCDAT scrnB Y-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display Y-patch control difference of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-M2
ARCDAT scrnB M-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display M-patch control difference of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-C2
ARCDAT scrnB C-clr ctrl differ (1/2 SPD)
Lv.2 Details
To display C-patch control difference of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
SUM-B-K2
ARCDAT scrnB Bk-clr ctrl differ(1/2 SPD)
Lv.2 Details
To display Bk-patch control difference of screen B in ARCDAT control
at 1/2 speed.
When hue variation occurs and the value shown is not in the
tolerable range, execute the auto gradation adjustment (reset the
target value). Check the Patch Sensor or replace the developer if not
alleviated.
Use case
When hue variation occurs
Display/adj/set range
-1023 to 1023
8-52
8-52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents