Check Items When Turning Off The Main Power; Installation Procedure - Canon imageRUNNER ADVANCE C5255 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

[13] Signal Cable
[14] IV Cable X 1
(660mm ; Red) X 1
FK2-8453 or
FK2-8432 or A: Cont-Sig
A: HDD-Pow1, A: HDD-Sig1
[16] HDD Drawer Unit x 1
[17] Screw (R round head
TP; M3x6) X 9
Use 6 of them
[19] R-HDD Label X 1

Check Items when Turning OFF the Main Power

Check that the main power switch is OFF.
1) Turning off the Main Power Supply Switch of the Host Machine.
2) Check that the display on the Control Panel and the Main Power Supply Lamp are turned
off before disconnecting the outlet.
9
Installation > [TYPE-3] > Installation Procedure > Removing the HDD Unit, Signal Cable and Power Supply Cable
[15] Power Cable
(650mm) X 1
■ Removing the HDD Unit, Signal Cable and Power Supply Cable
FK2-8464 or A: Cont-Pow
1) Open the Right Lower Cover. (Open the Right Upper Cover simultaneously.)
[18] Screw
(P Tight; M3x8) X 4
Use 2 of them
2) Open the Right Rear Cover 1.
3) Remove the Right Rear Cover 1.
• 1 screw (RS tight; M4)
• 2 screws (TP; M3)
• 1 claw
F-9-499
9
Installation > [TYPE-3] > Installation Procedure > Removing the HDD Unit, Signal Cable and Power Supply Cable

Installation Procedure

x3
9-191
F-9-500
Claw
F-9-501
9-191

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents