4
Parts Replacement and Cleaning > Image Formation System > Removing the Hopper (C) > Procedure
6) Remove the rail Retaining Plate.
• 4 screws (M4 binding)
x4
7) Remove the Toner Tray.
• 1 screw (M4 binding)
4
Parts Replacement and Cleaning > Image Formation System > Removing the Hopper (C) > Procedure
8) While avoiding the Duct Sheet, remove the Hopper Unit.
• 1 connector
• 4 screws
F-4-279
F-4-280
Connector
Hopper
Unit
x2
Duct Sheet
4-162
x2
F-4-281
4-162