Removing the Multi-purpose Tray Separation Roller

■ Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Duplex Unit.(Refer to page 4-186)
3) Removing the Multi-purpose Tray Pickup Roller.(Refer to page 4-187)
■ Procedure
1) While opening the Multi-purpose Tray Sub Cover, remove the Front Feed Guide.
• 1 Screw
• 2 Shaft Supports
• 2 Claws
Front Feed Guide
Shaft
Supports
4
Parts Replacement and Cleaning > Pickup Feed System > Removing the Multi-purpose Tray Separation Roller > Procedure
x2
Multi-purpose Tray
Sub Cover
Claws
F-4-362
2) While holding down the Multi-purpose Tray Separation Roller Shaft, remove the Middle
Feed Guide.
• 1 Screw
• 2 Shaft Supports
• 1 Claw
Middle Feed Guide
Shaft
Supports
Multi-purpose Tray
Separation
Roller Shaft
3) Remove the Multi-purpose Tray Separation Roller.
• 1 claw
Multi-purpose tray
separation roller
4-188
Claw
Multi-purpose Tray
Sub Cover
F-4-363
Claw
F-4-364