Installation Procedure
Installing the Scanner
DADF model only
1) Remove the 2 Scanner System Fixation Screws on the left side of the Reader Assembly.
2) Affix the below seal.
• 1 ADF Cable Seal
• 1 Face Seal
NOTE:
Be sure to keep the Scanner System Fixation Screws in a safe place to use for moving
the machine.
x2
9
Installation > Installation Procedure > Installing the Drum Unit
ADF Cable Seal
Face Seal
9
Installation > Installation Procedure > Installing the Drum Unit
Installing the Drum Unit
1) Remove the ITB Cover.
• 2 screws (to loosen)
2) Check that the ITB Sub Pressure Release Lever is positioned in the direction of the arrow
and if not, turn it and adjust the position.
direction
of the arrow
F-9-18
9-12
screw
F-9-19
ITB Sub Pressure
Release Lever
F-9-20
9-12