Operation Check Of The Main Controller Leds - Canon imageRUNNER ADVANCE C5255 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

Operation Check of the Main Controller LEDs

You may be able to determine the remedies against Main Controller-related troubles by
checking the lighting status of LEDs on the PCB.
■ Location of LEDs
LED1 Green
LED9 Green
LED16 Green
Main Controller PCB 1
Riser PCB
■ Preconditions
Check whether the Main Controller PCB 1 and the Main Controller PCB 2 are properly
inserted.
Check whether the connectors are securely connected. LEDs are not lit when the contaction
is poor. (Power-on is not possible)
When the LED of the Control Panel main power is not lit, check the connection of cables (such
as UI Cable).
6
Troubleshooting > Controller Self Diagnosis > Operation Check of the Main Controller LEDs > Checking the lighting of the LED4 RED on the Main Controller 2
LED 4 Red
Main Controller PCB 2
F-6-166
6
Troubleshooting > Controller Self Diagnosis > Operation Check of the Main Controller LEDs > Checking the lighting of the LED4 RED on the Main Controller 2
■ Checking■the■lighting■of■the■LED4■RED■on■the■Main■Controller■2■
Check the lighting of the LED on
the Main Controller PCB 2
LED4 is lit.
No
Yes
Normal operation
6-133
- Check for any blown-out fuse of the Relay Board
- Check whether the connector (on the Main
Controller PCB 2 side) is securely connected
F-6-167
6-133