Canon imageRUNNER ADVANCE C5255 Series Service Manual page 705

Hide thumbs Also See for imageRUNNER ADVANCE C5255 Series:
Table of Contents

Advertisement

E
Detailed
Occurance
Items
code
code
area
E020
0290
05
Title
Error in M Developing Assembly
Description Error in signal lower limit with ATR sampling detected
value
Remedy
1. Check if the ATR Sensor Connector is disconnected.
2. Check short-circuit of the ATR Sensor (TS6) Harness.
3. Replace the Developing Assembly.
E020
0291
05
Title
Error in M Developing Assembly
Description Error in signal upper limit with ATR sampling detected
value
Remedy
1. Check toner leak from the Toner Buffer Unit.
2. Check toner level in the Toner Container.
3. Replace the Developing Assembly.
4. Check short-circuit of the harness with the Toner Buffer
Supply Sensor (PS2).
E020
02B0
05
Title
Error in M Developing Assembly
Description TD ratio lower limit error at the time of print sequence
(Large amount of toner in the Developing Assembly)
Remedy
Go through the following: DISPLAY > DENS > DENS-M; if
DENS-M is slightly higher than 5.0%, output 10 sheets of
solid image with the color causing the error (to reduce T/D
ratio). See the Service Mode again to see if the problem
is improved. Remedy is complete if it's improved. If not,
perform the following remedy work.
1. Check if the ATR Sensor (TS6) Connector is
disconnected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020
02B1
05
Title
Error in M Developing Assembly
Description TD ratio upper limit error at the time of print sequence
(Small amount of toner in the Developing Assembly)
Remedy
1. Output 10 sheets of white (blank) sheets (to increase
T/D ratio).
2. Check toner leak from the Toner Buffer Unit.
3. Check toner level in the Toner Container.
4. Replace the Developing Assembly.
5. Check short-circuit of the harness of the Toner supply
sensor (PS2).
E020
0330
05
Title
Error in C Developing Assembly
Description The average of ATR reference value was lower than the
specified value at the time of ATR Sensor initialization.
Remedy
1. Check short-circuit of the ATR Sensor (TS7) Harness.
2. Replace the Developing Assembly.
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
E
Detailed
Occurance
Items
code
code
area
E020
0331
05
Title
Error in C Developing Assembly
Description The average of ATR reference value was higher than the
specified value at the time of ATR Sensor initialization.
Remedy
1. Check if the ATR Sensor (TS7) Connector is properly
connected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020
0340
05
Title
Error in C Developing Assembly
Description Unable to adjust the control voltage at the time of ATR
initialization: less than the specified value (3.2V).
Remedy
1. Check if the ATR Sensor (TS7) Connector is properly
connected.
2. Check short-circuit of the ATR Sensor Harness.
3. Replace the Developing Assembly.
E020
0341
05
Title
Error in C Developing Assembly
Description Unable to adjust the control voltage at the time of ATR
initialization: exceeds the specified value (6.8V).
Remedy
1. Check short-circuit of the ATR Sensor (TS7) Harness.
2. Replace the Developing Assembly.
E020
0390
05
Title
Error in C Developing Assembly
Description Error in signal lower limit with ATR sampling detected
value
Remedy
1. Check if the ATR Sensor Connector is disconnected.
2. Check short-circuit of the ATR Sensor (TS7) Harness.
3. Replace the Developing Assembly.
E020
0391
05
Title
Error in C Developing Assembly
Description Error in signal upper limit with ATR sampling detected
value
Remedy
1. Check toner leak from the Toner Buffer Unit.
2. Check toner level in the Toner Container.
3. Replace the Developing Assembly.
4. Check short-circuit of the harness with the Toner Buffer
Supply Sensor (PS3).
7-14
Description
7-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents