Panasonic FP7 Series Command Reference Manual page 33

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Operatio
Name
Carry-Flag
Reset
Data Processing Instructions
Operatio
Name
US, SS,
Data Search
UL, SL,
SF, DF
ON Bits Count
US, UL
US, SS,
Obtainment of
UL, SL,
the Max. Value
SF, DF
US, SS,
Obtainment of
UL, SL,
the Min. value
SF, DF
US, SS,
Obtainment of
the Total and
UL, SL,
the Mean
SF, DF
US, SS,
Sort
UL, SL,
SF, DF
US, SS,
Linearization
UL, SL,
SF, DF
Variance and
Standard
US, SS
Deviation
Acquisition
Event Count Instructions
Operatio
Name
Instruction to
Count the No.
UL
of Events
WUME-FP7CPUPGR-12
n
Mnemonic
Unit
CLC
(P)
n
Mnemonic
Unit
SRC
(P)
BCU
(P)
MAX
(P)
MIN
(P)
MEAN
(P)
SORT
(P)
SCAL
(P)
STDDEV (P)
n
Mnemonic
Unit
EVENTC
1.2 List of High-level Instructions
Operand
Function overview
Turns OFF the carry flag (SR9).
Operand
Function overview
Searches for the data of [S1] from the data
stored in [S2] to [S3], and stores the
S1, S2,
matching articles and the relative position
S3, D
of where the data first matched in the area
starting with [D].
Counts the number of ON bits in the data of
S, D
[S], and stores the number in [D].
Searches for the maximum value of the
data stored in [S1] to [S2], and stores the
S1, S2,
maximum value and the relative position of
D
where the maximum value was first
detected in the area starting with [D].
Searches for the minimum value of the data
stored in [S1] to [S2], and stores the
S1, S2,
minimum value and the relative position of
D
where the minimum value was first
detected in the area starting with [D].
Calculates the total and the average of the
S1, S2,
data stored in [S1] to [S2], and stores it in
D
the area starting with [D].
Changes the order of the data stored in
S1, S2,
[S1] to [S2]. The sorting conditions are
S3
specified in [S3] (descending order or
ascending order).
Creates a data table used for scaling
S1, S2,
(linearization) in the area starting with [S2].
D
Scales the data of [S1] (input value X), and
stores it in [D] (output value Y).
Stores the variance and standard deviation
within the range of the device area
S, n, D
specified by [S] and [n] into the device area
specified by [D].
Operand
Function overview
Counts the number of ON times for the [n]
S1, S2,
bits of the data specified by [S1], and
n, D
stores it in the area starting with [D].
Page
"P.9-11"
Page
"P.10-2"
"P.10-5"
"P.10-7"
"P.10-13"
"P.10-19"
"P.10-24"
"P.10-27"
"P.10-30"
Page
"P.10-33"
(Note 1)
1-15

Advertisement

Table of Contents
loading

Table of Contents