Panasonic FP7 Series Command Reference Manual page 46

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

1.2 List of High-level Instructions
(Note 1)
For GPSEND instruction, it is necessary to set the execution condition to ON from the time when the
instruction is started to the time when the sending flag turns OFF.
(Note 2)
For PMSET instruction, it is necessary to set the execution condition to ON from the time when the
instruction is started to the time when the processing flag turns OFF.
Communication Instruction (When Using FP7 Multi-Wire Link Unit)
Operatio
n
Name
Unit
Send
Instruction
(When Using
US, SS
FP7 Multi-Wire
Link Unit)
Receive
Instruction
(When Using
US, SS
FP7 Multi-Wire
Link Unit)
Acquiring
MEWNET-W
Parameters
Obtainment of
MEWNET-W2
Parameters
Obtainment of
MEWNET-F
Parameters
Change of
MEWNET-W
Parameter
Change of
MEWNET-W2
Parameter
1-28
Mnemonic
Operand Function overview
S, n, D1,
SEND
(P)
D2, D3
S1, S2,
n,
RECV
(P)
D1, D2
PMGET
(P)
S, D
PMGET
(P)
S, D
PMGET
(P)
S, D
PMSET
S, n, D
pPMSET
S, n, D
PMSET
S, n, D
pPMSET
S, n, D
Data can be transferred from the master
unit to the partner unit between PLCs
connected by MEWNET-W or MEWNET-
W2.
Reads the data from devices within the
master unit starting with [S], and stores the
data in the partner station number [D1]
from the address starting with [D2]. The
number of sent data is specified by [n].
Data can be transferred from the partner
unit to the master unit between PLCs
connected by MEWNET-W or MEWNET-
W2.
Reads the data from the partner station
number [S1] from the address starting with
[S2], and stores it in the device of the
master unit starting with [D1]. The number
of received data is specified by [n].
Reads the communication status set for
MEWNET-W and the operations of the PLC
link, and stores them in the area starting
with [D].
Reads the communication status set for
MEWNET-W2 and the operations of the
PLC link, and stores them in the area
starting with [D].
Reads the communication status set for
MEWNET-F, and stores it in the area
starting with [D].
The data stored in the area of [n] words
starting with [S] is set for the
communication parameter of MEWNET-W.
For PMSET instruction, the
acknowledgment process is performed
when the instruction is executed. For
pPMSET instruction, the acknowledgment
process is performed when the scan is
finished.
The data stored in the area of [n] words
starting with [S] is set for the
communication parameter of MEWNET-
W2.
For PMSET instruction, the
acknowledgment process is performed
when the instruction is executed. For
pPMSET instruction, the acknowledgment
Page
"P.16-2"
"P.16-6"
"P.16-10"
"P.16-14"
"P.16-18"
"P.16-20"
"P.16-23"
WUME-FP7CPUPGR-12

Advertisement

Table of Contents
loading

Table of Contents