1.2 List of High-level Instructions
Operatio
n
Name
Unit
Time
adjustment
request
(Note 1)
Can be used with CPU units CPS4RE*/CPS3RE*.
Ethernet Communication Instruction (FTP Client)
Operatio
n
Name
Unit
FTP client
connected
server setting
FTP client
transfer setting
FTP client
logging/trace
transfer setting
FTP client
transfer
request
FTP client
transfer control
(Note 1)
Can be used with CPU units CPS4RE*/CPS3RE*.
Ethernet Communication Instruction (HTTP Client)
Operatio
n
Name
Unit
HTTP client
connected
server setting
HTTP client
transfer setting
HTTP client
transfer
request
HTTP client
transfer control
(Note 1)
Can be used with CPU units CPS4RE*/CPS3RE*.
1-30
Mnemonic
Operand Function overview
S1, S2,
pNTPcREQ
D
Mnemonic
Operand Function overview
S1, S2,
FTPcSV
(P)
S3
FTPcSE
S1, S2,
(P)
T
S3, S4
FTPcLO
S1, S2,
(P)
G
S3
FTPcRE
(P)
S
Q
FTPcCT
(P)
S1, S2
L
Mnemonic
Operand Function overview
HTTPcS
S1, S2,
(P)
V
S3
HTTPcS
S1, S2,
(P)
ET
S3, S4
HTTPcR
(P)
S
EQ
HTTPcC
(P)
S1, S2
TL
Requests the time adjustment.
Sets the FTP server of the connection
destination to the CPU unit according to the
parameters specified by [S1], [S2], and
[S3].
Sets and stores the FTP client transfer
settings of [S2] to [S4] to the transfer
setting area specified by [S1].
Sets and stores the logging trace transfer
settings of [S2] to [S3] to the logging trace
transfer settings area specified by [S1].
Requests a transfer of the FTP client
transfer No. specified by [S].
Controls whether to enable, disable, or
cancel the transfer of the FTP client,
according to the specification of the control
description [S2] for control target [S1].
Sets the HTTP server of the connection
destination to the CPU unit according to the
parameters specified by [S1], [S2], and
[S3].
Sets and stores the HTTP client transfer
settings of [S2] to [S4] to the transfer
setting area specified by [S1].
Requests a transfer of the HTTP client
transfer No. specified by [S].
Controls whether to enable, disable, or
cancel the transfer of the HTTP client,
according to the specification of the control
description [S2] for control target [S1].
Page
"P.17-47"
(Note 1)
Page
"P.17-52"
(Note 1)
"P.17-59"
(Note 1)
"P.17-69"
(Note 1)
"P.17-73"
(Note 1)
"P.17-77"
(Note 1)
Page
"P.17-81"
(Note 1)
"P.17-87"
(Note 1)
"P.17-94"
(Note 1)
"P.17-98"