Replacing SRX5400 Services Gateway SPCs

Removing an SRX5400 Services Gateway SPC

Copyright © 2014, Juniper Networks, Inc.
CAUTION:
Do not leave a fiber-optic transceiver uncovered except when
inserting or removing cable. The safety cap keeps the port clean and
prevents accidental exposure to laser light.
Insert the cable connector into the cable connector port on the faceplate.
3.
NOTE:
The cages and optics on the components are industry standard
parts that have limited tactile feedback for insertion of optics and fiber.
You need to insert the optics and fiber firmly until the latch is securely in
place.
Arrange the cable in the cable manager to prevent it from dislodging or developing
4.
stress points. Secure the cable so that it is not supporting its own weight as it hangs
to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners
on the loop helps to maintain its shape.
CAUTION:
Avoid bending fiber-optic cable beyond its minimum bend
radius. An arc smaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
CAUTION:
Do not let fiber-optic cable hang free from the connector. Do
not allow fastened loops of cable to dangle, which stresses the cable at
the fastening point.
Connecting Network Cables to SRX5400 Services Gateway MICs on page 61
Maintaining SRX5400 Services Gateway Network Cables on page 86
To replace an SPC, perform the following procedures:
1.
Removing an SRX5400 Services Gateway SPC on page 131
Installing an SRX5400 Services Gateway SPC on page 133
2.
An SPC weighs up to 18.3 lb (8.3 kg). Be prepared to accept its full weight.
Chapter 13: Replacing SRX5400 Services Gateway Hardware Components
131