Table 26: Ac Power Electrical Specifications For The Jcs 1200 Platform - Juniper JCS 1200 Hardware Manual

Juniper control system platform
Hide thumbs Also See for JCS 1200:
Table of Contents

Advertisement

Juniper Control System (JCS) 1200 Platform Hardware Guide
CAUTION: To comply with intrabuilding lightning and surge requirements,
intrabuilding wiring must be shielded, and the shield for the wiring must be grounded
at both ends.
Related Topics
AC Power Supply Electrical Specifications for the JCS 1200 Platform
Table 26 on page 190 lists the AC power system and power supply electrical
specifications.

Table 26: AC Power Electrical Specifications for the JCS 1200 Platform

Related Topics
Power Consumption for an AC-Powered JCS 1200 Platform
Table 27 on page 191 lists the power requirements for base AC-powered routers
operating under typical voltage conditions and includes nonredundant and redundant
power supply configurations.
190
AC Power Supply Electrical Specifications for the JCS 1200 Platform
AC Power Supply Electrical Specifications for the JCS 1200 Platform on page 190
Power Consumption for an AC-Powered JCS 1200 Platform on page 190
DC Power Supply Electrical Specifications for the JCS 1200 Platform on page 192
Power Consumption for a DC-Powered JCS 1200 Platform on page 192
Item
Power System
AC input voltage
AC input line frequency
AC system current rating
AC system input power
Power Supply
Maximum output power
AC input line frequency
Site Electrical Wiring Guidelines for the JCS 1200 Platform on page 189
Power Consumption for an AC-Powered JCS 1200 Platform on page 190
Connecting the JCS 1200 AC Platform to AC Power on page 62
Specification
Operating range: 200 to 240 VAC
50 to 60 Hz (nominal)
32 A @ 220 VAC (16 A per inlet)
8000 W
2880 W
50 to 60 Hz (nominal)