Remove the interposer from switch module bays 7 and 8:
7.
Pull the switch module interposer release handle to the open position. The
a.
interposer moves out of the bay approximately 0.25 in. (0.6 cm).
Slide the interposer out of the bay.
b.
Attach the bezel collar to the JCS 1200 platform (see Figure 38 on page 100):
8.
Insert the lower bezel collar hooks into the bezel mounting slots on the
a.
bottom of the JCS 1200 platform; then rotate the top of the frame up until
the upper collar hooks are inserted into the mounting slots.
Push down on the bezel collar to completely engage the collar hooks in the
b.
mounting slots.
NOTE: The top of the collar should be flush with the top of the chassis.
Secure the bezel collar to the JCS 1200 platform by using a Phillips-head
c.
screwdriver to tighten the captive mounting screws on the cable management
trays (see Figure 43 on page 105).

Figure 43: Securing the Cable Management Trays

Reinstall the management module interposer into management module bay 1:
9.
Make sure that the release handle on the interposer is in the open position.
a.
Slide the interposer into the management module bay until it stops.
b.
Chapter 10: Replacing Components in a JCS 1200 Platform
Installing a JCS 1200 Bezel Collar
105