Figure 63: Removing and Installing a JCS 1200 Management Module

To install a management module or module filler (see Figure 63 on page 126):
1.
2.
3.
4.
5.
6.
7.
8.
9.
Related Topics
126
Installing a JCS 1200 Management Module or Module Filler
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis.
Remove the management module filler, if one is installed.
Remove the management module interposer filler tray, if one is installed.
Install the management module interposer, if it is not already installed.
Make sure that the release handle on the management module is in the open
position.
Slide the management module into the management module bay until it stops.
Push the management module release handle to the closed position.
Connect any cables to the management module.
If the JCS 1200 platform is connected to power, make sure that the
the management module is lit. If the management module is redundant, wait at
least 45 minutes for the modules to copy the configuration data before you make
any changes to the management module configuration.
Preventing Electrostatic Discharge Damage to the JCS 1200 Platform on page 154
JCS 1200 Management Module Description on page 15
Replacing a JCS 1200 Management Module Filler Tray on page 127
Locating the JCS 1200 Management Module Serial Number on page 199