By default, the management module is configured to respond to DHCP first before
using its static IP address.
The client computer that you connect to the management module must be configured
to operate on the same subnet as the management module. The IP address of the
management module must also be in the same local domain as the client computer.
To connect to the management module for the first time, you must change the IP
properties on the client computer.
You can use one of two interfaces to connect to the management module for the
first time. If you are connecting to the management module through an Ethernet
connection, you can Telnet to the management module and use the CLI to configure
the module. If you are connecting through a serial connection, you can use a terminal
emulator to access the CLI.
The following topics describe how to establish a session between a client computer
and the management module to perform initial configuration of the JCS 1200 platform.
Establishing Your JCS 1200 Management Module Connection Using a Direct Ethernet
Connection
After you connect the Ethernet cable from the management module to the client
computer:
1.
2.
3.
After you connect the client computer to the management module for the first time,
perform initial configuration of the JCS 1200 platform. See the JUNOS Protected System
Domain Configuration Guide for configuration instructions.
Establishing Your JCS 1200 Management Module Connection Using a Direct Serial
Connection
After you connect the serial cable from the management module to the client
computer:
1.

Establishing Your JCS 1200 Management Module Connection Using a Direct Ethernet Connection

Establishing Your JCS 1200 Management Module Connection Using a Direct
Ethernet Connection on page 71
Establishing Your JCS 1200 Management Module Connection Using a Direct Serial
Connection on page 71
Make sure that the subnet of the client computer is set to the same value as the
default management module subnet (255.255.255.0).
Open a console window and log in to the default management module IP address
(192.168.70.125).
Enter the default user name, USERID, and the default password, PASSW0RD
(note the number zero, not the letter O, in PASSW0RD), to start the remote
session.
Make sure that the serial port of the client computer is set to the following
settings:
Baud rate—57600
Parity—none
Chapter 7: Connecting the JCS 1200 Platform
71