Chapter 5
Installing the JCS 1200 Mounting
Hardware

JCS 1200 Platform Rack-Mounting Hardware

Related Topics

Rack Mounting Hole Locations for the JCS 1200 Platform

This chapter describes the procedures for installing the mounting hardware:
JCS 1200 Platform Rack-Mounting Hardware on page 43
Rack Mounting Hole Locations for the JCS 1200 Platform on page 43
Installing the JCS 1200 Mounting Hardware for a Four-Post Rack or
Cabinet on page 44
Installing the JCS 1200 Mounting Hardware for an Open-Frame Rack on page 46
The JCS 1200 platform can be installed in a four-post rack or cabinet or an open-frame
rack. Before you install the JCS 1200 platform, you install the mounting hardware
on the rack. The procedure for installing the mounting hardware depends on the
type of rack.
All mounting options require that you to install the supplied large mounting shelf.
The supplied small mounting shelf is needed only for a four-post rack or cabinet.
Rack Mounting Hole Locations for the JCS 1200 Platform on page 43
Rack-Mounting Requirements and Warnings for the JCS 1200 Platform on page 156
Installing the JCS 1200 Mounting Hardware for a Four-Post Rack or
Cabinet on page 44
Installing the JCS 1200 Mounting Hardware for an Open-Frame Rack on page 46
Table 19 on page 44 specifies the holes in which you insert mounting screws (and
cage nuts if needed) to install the mounting hardware required in a four-post or
two-post open-frame rack (an X indicates a mounting hole location). The hole distances
are relative to one of the standard U divisions on the rack. The bottom of all mounting
shelves is at 0.04 in. (0.02 U) above a U division.
JCS 1200 Platform Rack-Mounting Hardware
43