Initial Start-Up - Interlogix ATSx500A Series Installation And Programming Manual

Advisor advanced
Table of Contents

Advertisement

Chapter 4: Programming

Initial start-up

When switched on first time, the system prompts you to perform an installation.
INFO
Inst required
Caution:
It is only possible to perform the initial system installation from
keypad 1.
It is necessary to set appropriate default values for this particular system prior to
programming. The following settings can be defined during installation.
Table 23: Values set during installation
Option
Default value
1 Panel language
English UK
2 Defaults
EN 50131
3 Duress method
Disabled
4 PIN length
4
5 Time and date
Depends on the
firmware version
6 Install
Cancel
*
Contact your supplier for a list of available languages and approved versions.
Set the appropriate options and run the installation, then choose OK and press
Enter. The following messages are displayed:
Installer
PIN:1278
Supervisor
PIN:1122
1278 is the default PIN for master installer, and 1122 is the default PIN for a
supervisor.
Note:
If the PIN length is configured for more than 4 digits, zeroes are added to
the default PIN values. For example, if the system is configured for 6-digit PINs,
the master installer PIN is 127800.
Confirm each screen with Enter.
114
Description
Defines the language* of the panel menus. This
language is used for messages when no user is
logged in. After login the language is switched to
the one assigned to the logged user (set by
system manager).
Defines approval* dependent default values.
Default duress method. See Advisor Advanced
Manager Manual for more information.
Default length of PIN (allowed range is from 4 to
10). See "8.7.4 PIN length" on page 250 for more
details.
Time and date must be set during installation. See
also "8.1.1 Time and date" on page 232.
Run the installation process
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual