The macros timers
The output has many timed and a latched option. Each of the timed options may
be programmed in minutes or seconds within the range of 1 to 255.
Disabled: Macro is disabled.
Non-timed: Follows the result of the logic equation only. If a macro input (an
event flag or an output) for this macro changes, the logic equation will be
calculated again.
On pulse [s]: Activates for the programmed time (in seconds) or the active
period of the logic result, whichever is the shortest.
On pulse [m]: Activates for the programmed time (in minutes) or the active
period of the logic result, whichever is the shortest.
On timed [s]: Activates for the programmed time (in seconds) regardless of
the macro output changing.
On timed [m]: Activates for the programmed time (in minutes) regardless of
the macro output changing.
On delay [s]: Activates after the programmed time period (in seconds) unless
the result of the logic equation is no longer valid.
On delay [m]: Activates after the programmed time period (in minutes) unless
the result of the logic equation is no longer valid.
Off delay [s]: Follows the result of the logic equation, but remains active for
the time (in seconds) programmed after the result of the logic equation is no
longer active.
Off delay [m]: Follows the result of the logic equation, but remains active for
the time (in minutes) programmed after the result of the logic equation is no
longer active.
Latched: Activates on any of the first three macro inputs in the logic equation
and is only reset by the fourth macro input. Any programmed AND / OR
function is not used.
Note:
In the Latched mode, the reset input 4 will not reset the macro's output
while any of the inputs (1, 2, or 3) are active.
Pulsed lock and unlock
This function is only used on special electronic locks that require two separate
relays to be pulsed at different times for it to open, and two separate zones for
monitoring.
The two relay needed are taken from the relay specified in menu "5.1 Doors" on
page 196. The "5.1.n.4 Door output" on page 198 specifies one relay, and door
controller takes the next sequential relay number for the second relay it needs to
operate the lock. For example; if output 17 is entered as an Unlock output
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Chapter 3: System functions
71