Interlogix ATSx500A Series Installation And Programming Manual page 186

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
4.1.n.6.31 EE set check
31 EE set check
>No<
If set to yes, entry/exit or access zone must be in a normal state when setting the
area. Otherwise, the user is not allowed to set premises until the problem is
solved.
The option is only available for entry/exit and access type zones.
4.1.n.6.32 Alarm in PS1
32 Alarm in PS1
>No<
If the option is set to yes, entry/exit zone becomes an alarm zone during part
set 1.
Notes
The option is only available for entry/exit type zones. See "Zone types" on
page 45
The zone must be included into part set 1. See "4.1.n.6.3 Excl. in PS1" on
page 174.
Zone functionality does not change if the same zone belongs to an area in full
set state.
4.1.n.6.33 Alarm in PS2
The same as "4.1.n.6.32 Alarm in PS1" above, but for part set 2.
4.1.n.6.34 Report as
34 Report as
>Panic (PA)<
Defines how panic alarm is reported to central stations.
Report as panic: PA event is reported.
Report as duress: HA event is reported.
See Appendix B "Advisor Advanced reporting codes" on page 327 for details.
Notes
This option is only available for panic type zones. See "Zone types" on page
45.
The option is only available when Panic mode is set to Silent. Otherwise
panic alarm is always reported as PA event. See "8.8.1 Panic mode" on page
254.
180
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual