Chapter 5: Menu reference
4.1.n.6.13 Shock sensor
13 Shock sensor
>No<
The Shock sensor option activates the shock sensor functionality. If this option is
set to Yes, the zone operates according to the settings configured in "4.1.n.7
Grs&Pls options" (see page 182).
Only the first eight inputs on the control panel and first eight on the input
expander support this option.
4.1.n.6.14 Extend EE
14 Extend EE
>No<
If the Extend EE option is Yes, the zone activation expands the entry time for the
value defined by "4.2.n.4.2 Prealarm time" on page 187.
Note:
After entry timer times out, local alarm activates.
4.1.n.6.15 Final door
15 Final door
>No<
When the Final door option is set to Yes, the zone has the exit terminator
functionality. If the zone is activated during the exit time, the exit timer is
terminated after the Final Set delay has expired (see "8.1.3.5 Final set delay" on
page 235) and the area is set.
4.1.n.6.16 Key latch
16 Key latch
>No<
If the Key latch option is set to Yes, the key switch zone input is latching. If the
zone state is active, the area is set. If the zone changes to normal, the area is
unset.
If set to No, the input needs both states to toggle between set and unset (pulse
key switch).
4.1.n.6.17 Key set
17 Key set
>Off<
The Key set option defines the zone as a key switch for area set. The following
options are available:
Off: the area set is not affected by the zone.
Key part set: zone is a key switch for area part set.
Key full set: zone is a key switch for area full set.
176