Interlogix ATSx500A Series Installation And Programming Manual page 320

Advisor advanced
Table of Contents

Advertisement

Appendix A: Advisor Advanced events
Group
Event
ZNAM
ZNTAMPER
KEYPADTAMPER
KEYPADFAULT
EXPANDERTAMPER
EXPANDERFAULT
DURESS
FSDURESS
PSDURESS
USDURESS
FTCDURESS
CODETAMPER
ENTRY
EXIT
EXITFAULT
RTS
SETOK
SETFAULT
UNSETOK
ALARMACK
FIRERESET
314
#
Event description
46
Zone masking
47
Zone tamper
48
Keypad tamper
49
Keypad fault
50
Expander tamper
51
Expander fault
52
Duress
53
Duress during full
set
54
Duress during part
set
55
Duress during
unset
56
Duress and FTC
57
Code tamper
58
Area entry
59
Area exit
60
Exit fault
61
Ready To Set
62
Area set OK
63
Area set failed
64
Area unset OK
65
Alarms to ACK
66
Fire reset
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Notes
At least one zone in the area is
in anti-mask alarm state
At least one zone in the area is
in tamper state
A keypad assigned to the area is
in tamper state
A keypad assigned to the area is
in fault state
An expander assigned to the
area is in tamper state
An expander assigned to the
area is in fault state
Duress code used in the area
Duress code used while area full
set
Duress code used while area
part set
Duress code used while area
unset
Duress code used while FTC
present
Active when a
keypad
assigned
to the area is locked for 2
minutes due to 3 wrong PIN
entries
Area entry time is active
Area exit time is active
Alarm detected during exit state
before changing to part or full
set state
Active when all configured RTS
conditions are valid
Active for 2 s when area set
successfully
Active during 30 s after
unsuccessful area setting
Active for 2 sec when area has
been unset
Alarms present waiting for
acknowledge
For FIRE zone, event active for
10 s after fire alarm
acknowledge (also inhibits fire
zone for 15 s). Also active for 10
s during fire zone walk test

Hide quick links: