Chapter 5: Menu reference
5.1.n.4 Door output
0>Not used
17 Output 17
Select unlock door output.
For intelligent doors, the output must belong to the appropriate door controller
outputs range.
You can also select an output that cannot be directly controlled from the Advisor
Advanced system. See "8.5.2.1 Map relays" on page 247 for details.
You cannot select outputs that are already assigned to Forced door, Warning,
DOTL or other output.
It is recommended to use one of first four door controller outputs for door unlock.
5.1.n.5 Door timers
1>Unlock time
>>>
Use the menu to configure various timers for the selected door.
Note:
For standard doors, the timer value is set in minutes and seconds in
mm'ss format, for example, 01'30.
In case of intelligent doors, use two options placed as submenus:
1. Time: Set the time value from 0 to 127.
2. Resolution: Set units (seconds or minutes) for the time value above.
5.1.n.5.1 Unlock time
1>Time
0
Program the amount of time (value and units) for the door to unlock when a user
enters a valid card or PIN at the door reader.
5.1.n.5.2 Extended time
1>Time
0
Program the amount of time (value and units) for the door to unlock when a user,
with the "Extended access" option enabled, presents a valid card or PIN at the
door reader. See also "3.1.n.8.4 Extended access" on page 167.
5.1.n.6 Door options
1 Door zones
>>>
The menu contains various options for the selected door.
For options related to intelligent doors, see "Intelligent door specific options" on
page 204.
198
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual