Note:
Particular events can only be inputs, while some events can be used as
outputs only.
2.2.2.n.4.8.m.2.y Select Operator
All events are joined with logical operators. Choose the operator to change it.
Valid operators are AND and OR.
2.2.2.n.4.8.m.3 Macro output
3>Macro output
>>>
Configure the output of the selected macro.
2.2.2.n.4.8.m.3.1 Output Func.
1 Output func.
>Non-timed<
Output functions are described in "Door controller macro logic" on page 70.
2.2.2.n.4.8.m.3.2 Duration
2 Duration [s]
>
<
Provide the duration for the output function from the previous menu.
Units are shown in the menu title. The allowed range is 1 to 255.
2.2.2.n.4.8.m.3.3 Activate
1>Group
Door
Select the output event the same way as you configure the input event. See
"2.2.2.n.4.8.m.2.x Select event" on page 158 for details.
2.2.2.n.4.8.m.4 Delete macro
4 Delete macro
>Cancel<
Use the command to remove a macro from the door controller. To remove the
macro, select Ok and press Enter.
2.2.2.n.4.9 Local Devices
The menu is equal to "2.2.3 DC/LC Exp Rdrs", but applies only to readers
connected to the local bus of the selected door controller. Refer to "2.2.3 DC/LC
Exp Rdrs" on page 160.
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual