Interlogix ATSx500A Series Installation And Programming Manual page 253

Advisor advanced
Table of Contents

Advertisement

8.5.1.3 Multiple badge
3 Multiple badge
> <
This setting is only applicable where the door has been programmed so that
presentation of a card three times will arm/disarm the system and the user is
authorised to arm /disarm.
The Multiple badge time is the amount of time allowed between the first
presentation of the card and the third presentation of the card. If the card is not
presented three times before the time expires, the user will need to commence
the function again.
8.5.1.4 Re-lock delay
4 Re-lock delay
> <
This setting only applies where the door has been programmed so the unlock
relay will not re-lock until after the door is closed.
This feature is provided for Drop Bolts and Maglocks etc. where the door must be
closed before the unlock relay locks the door.
The Re-lock delay time is the amount of time between the door being closed and
the unlock relay deactivating (re-lock). This allows a settling time to ensure that
the lock mechanisms are aligned.
8.5.2 DGP options
1>Map relays
No
The menu contains door controller settings.
8.5.2.1 Map relays
1 Map relays
>No<
Defines whether door controller unlock outputs can be controlled as standard
outputs.
Yes: Door unlock outputs can be controlled by the control panel as its
outputs.
No: Door unlock outputs can only be activated by door controller when using
door unlock user menu, or upon presenting a valid card.