Interlogix ATSx500A Series Installation And Programming Manual page 220

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
The functionality is configured separately for each door reader. After selecting
the option, choose the appropriate reader, and then set the option value.
5.1.n.9.4 HSU options
1>Req HSU Nr
0
The menu contains high security options.
See Chapter 3 "System functions > High security" on page 70 for details.
5.1.n.9.4.1 Req HSU Nr
1 Req HSU Nr
>0<
The value defines how many High Security Users (HSU) must be present in the
region assigned to the selected door.
5.1.n.9.4.2 Prewarn. time
2 Prewarn. time
> <
The value defines time (in seconds) for the prewarning timer to run. When there
are too few high security users in a high security region, a prewarning timer
starts, and when it expires, an alarm is raised and the alarm output activates.
5.1.n.9.4.3 HS alarm out
00>Not used
19 Output 17
Select an output on the door controller to indicate an anti-passback or high-
security alarm.
5.2 Door groups
0>Add Door Gr
1 Door Gr 1
Door groups define when a user can have an access to specific doors.
See Chapter 3 "System functions > Door groups" on page 69 for details.
5.2.0 Add Door Gr
Access the menu to add a door group. If the door group is created successfully,
the following message appears:
INFO
Door Gr added
The new door group is given the default name "Door Gr N" and placed on the
end of the door list.
214
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents