Interlogix ATSx500A Series Installation And Programming Manual page 159

Advisor advanced
Table of Contents

Advertisement

Note:
Before removing an expander, you should delete any outputs or condition
filters connected to the expander.
Wireless specific options
2.2.2.n.4.4 Supervision
1>Short superv.
20
The supervision is used to disable arming if the wireless expander does not
receive a supervision message from a sensor within the short supervision time.
A programmable supervision function checks the state of the devices in the field.
The supervision timers in the sensors are "dithered" by a small time so that
transmissions occur on a random basis with the effect of minimizing collisions in
larger installations.
Notes
Two- and four-button fobs don't transmit supervision signals
Supervision time cannot be set for individual sensors, only for individual
wireless expanders
2.2.2.n.4.4.1 Short superv.
1 Short superv.
>20<
Short supervision is used to disable arming if the wireless expander does not
receive a supervision message from a sensor within the short supervision time.
The allowed range is 20 to 1920 minutes.
2.2.2.n.4.4.2 Long superv.
2 Long superv.
>20<
Long supervision sets an alarm condition in the panel for a sensor which
supervision timer expired. Program the supervision time to control how often the
wireless expander checks the sensor is communicating and in range of the
wireless expander.
The allowed range is 20 to 1920 minutes.
2.2.2.n.4.4.3 Smoke superv.
3 Smoke superv.
>65<
Smoke supervision sets a fault condition in the panel when a detector
supervision timer expired. Program the supervision time to control how often the
wireless expander checks that the sensor is communicating and in range of the
wireless expander.
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual