Chapter 5: Menu reference
6.2.n.7 Parameters
1>Delay time
00:00'00
Set the appropriate parameters for the functions described above.
6.2.n.7.1 Delay time
1 Delay time
>00:00'00<
Delay time defines the time between an activation of the condition and switching
the output on. Allowed range is 00:00'00 to 12:00'00. 00:00'00 means that the
output is activated with no delay.
6.2.n.7.2 Active time
2 Active time
>00:00'01<
Active time defines the time of an activation of the output. Allowed range is
00:00'01 to 12:00'00.
This option is available only if Pulsed or Double pulsed mode is selected in
"6.2.n.6 Mode" on page 220.
6.2.n.7.3 Retriggerable
3 Retriggerable
>No<
Note:
The Retriggerable option is only valid for Pulsed and Double pulsed
outputs.
If this option is set to Yes, the active timer is restarted when the starting condition
becomes valid again during the active state, so the active time is prolonged.
Figure 27 below shows the output retrigging when the start filter is reactivated [1].
Figure 27: Output examples
(1)
(2)
(3)
(4)
(1) Start filter
(2) Stop filter
(3) Pulsed mode, not retriggerable
(4) Pulsed mode, retriggerable
222
[1]
t
t
A
B
t
t
t
A
C
B
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
t
t
A
C
t
t
A
C
t
Delay time
A
t
Active time
B
t
Interrupted active time
C