Interlogix ATSx500A Series Installation And Programming Manual page 42

Advisor advanced
Table of Contents

Advertisement

Chapter 2: Installation
Maximum voltage at power supply, auxiliary
power output and battery power output
Battery low condition
Battery test level [6]
Minimum voltage (battery recharging) at
power supply, auxiliary power output and
battery power output [7][8]
Maximum ripple voltage V, p-p [9]
Overvoltage trigger value [10]
[1] The power supply voltage is monitored according EN 50131 Grade 3 and VdS-C regulations.
[2] Current available for auxiliary power and battery charge outputs.
[3] Maximum permanent current to power devices external to the control equipment in the
absence of alarm conditions. The sum of the auxiliary and COMM power output current
cannot exceed the maximum current specified in "Auxiliary current and battery capacity" on
page 39.
[4] Battery output provides battery shortcut protection (according to VdS requirements).
[5] The housings applicable for particular batteries are specified in "Auxiliary current and battery
capacity" on page 39.
[6] If during a manual or a programmed battery test the battery voltage drops below this
threshold, the battery test fails.
[7] Deep discharge protection mechanism monitors the battery voltage and disconnects the
battery if the voltage falls below indicated value, as required by EN 50131 Grade 3 and VdS-
C regulations.
[8] A specific fail message is generated when any output fails.
[9] Max ripple voltage only when empty battery is charging.
[10] Overvoltage protection mechanism monitors the power supply voltage and shuts down the
PSU if the voltage raises above indicated value, as required by EN 50131 Grade 3 and VdS-
C regulations.
General features
Code combinations
End-of-line resistor
Onboard zones
Maximum zone number
Onboard outputs
Maximum output number
Areas
Area groups
Maximum keypad / RAS number
Maximum expander / DGP number
[1] It is necessary to install ATS670 second RS485 LAN extension module to connect more
than 16 RASes and 15 DGPs.
36
14.5 V
From 9.5 to 10.5 V
11.2 V
9.45 V
100 mV typical, 300 mV max.
15.5 V
min.
ATS1500A(-IP)
ATS3500A(-IP)
From 10,000 (4 digits) to 10 billion (10 digits)
1 kΩ, 1.5 kΩ, 2 kΩ, 2.2 kΩ, 3.3 kΩ, 3.74 kΩ,
4.7 kΩ (default), 5.6 kΩ, 6.8 kΩ, 8.2 kΩ, 10 kΩ
8 (expandable to 16 with 1X ATS608)
32
5 (expandable to 9 with 1X ATS624, or to 21 with
1X ATS626).
See "Standard onboard outputs" on page 37.
4
8
7
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
ATS4500A-IP
128
512
128
8
64
64
16
32 [1]
15
30 [1]

Hide quick links:

Advertisement

Table of Contents
loading