Siren Connection; Other Connections - Interlogix ATSx500A Series Installation And Programming Manual

Advisor advanced
Table of Contents

Advertisement

Chapter 2: Installation

Siren connection

Figure 20: Siren connection examples
S4 S5
S1 C
S2 C
LC-OUTPUTS
HC-OUTPUTS
(1)
(1)
(2)
(2)
(1) Siren EOL resistor (1 kΩ). It must be
installed if siren does not contain a
built-in resistor.
(2) Siren.
Note:
Siren output can be configured as internal or external. This is accomplished via panel
settings, not by configuring the panel hardware. See "Default output assignments" on page 31
and "Outputs" on page 67.

Other connections

Tamper connection
Figure 21: Earthing and tamper connection in ATSx500A(-IP)
PSTN connection
To connect PSTN in ATSx500A(-IP) control panels, use ATS7700 PSTN module.
See ATS7700 PSTN Module Installation Sheet for details.
Caution:
If the PSTN line is provided via the ADSL network, make sure that at
least ADSL splitter/filter is used, otherwise the PSTN communication quality may
be too low for a reliable reporting.
28
S3 C
-
-
T
C
SIR TMP
AUX POWER
(4)
(1)
(2)
(5)
( ) 1
( ) 2
( ) 3
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
S4 S5
S1 C
S2 C
LC-OUTPUTS
HC-OUTPUTS
(1)
(1)
(2)
(2)
(3) Beacon.
(4) Siren tamper EOL resistor.
(5) Siren tamper (normally closed).
(1) Earthing
(2) External tamper (normally closed)
(3) Optional pry-off tamper (normally
closed) required by EN 50131
Grade 3 and VdS-C regulations
S3 C
-
-
T C
SIR TMP
AUX POWER
(4)
(5)
(3)

Hide quick links:

Advertisement

Table of Contents
loading