Chapter 5: Menu reference
4.1.n.8.2 Block assign
Start input
>>>
Use the Block assign menu to copy all selected zone parameters to a range of
inputs, creating the appropriate zones.
Select a start and the end of device input range.
The system creates or modifies the existing zones with parameters equal to the
selected zone (except names that are default).
Note:
Copying zone parameters does not copy a wireless device. The device
must be programmed separately. See "4.1.n.7 RF details" on page 183 for more
details.
4.1.n.9 Move zone
004>Not used
009 Not used
Allows you to move the selected zone to other available zone number.
This option is only available in a flexible zone numbering scheme. See "8.7.9
Object scheme" on page 253 for details.
See also "Zone, output, and door addressing" on page 31.
4.1.n.10 Delete zone
10 Delete zone
>Cancel<
Use the Delete zone command to remove a zone from the system. To remove
the zone, select Ok and press Enter. The zone is deleted.
Notes:
In case of a wireless device, the device is also removed from the wireless
expander database.
Caution:
If the zone is assigned to a two-zone RF device, both zones are
deleted. See "Two-zone RF sensors" on page 96 for more details.
Shock sensor options
4.1.n.7 Grs&Pls options
7>Grs&Pls opts
>>>
The Gross and Pulse options are valid if the "4.1.n.6.13 Shock sensor"
functionality (see page 176) for this zone is set to Yes.
182
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual