Chapter 5: Menu reference
Note:
If zones are assigned to more than one area, the longest prealarm time is
used. See "4 Zones and areas" on page 171.
4.2.n.4.3 Unset delay
3 Unset delay
>
<
Set a delay for authorized unset (in minutes). The allowed range is 1 to 30 min.
0 means that no delay is applied. See "Delayed unset" on page 52 for more
details.
4.2.n.5 Set/unset options
1>Entry alarms
Delayed
The menu groups the following setting options.
4.2.n.5.1 Entry alarms
1 Entry alarms
>Delayed<
The Entry alarms option defines whether the entry fail alarm is reported
immediately. The following values are applicable:
Delayed: The alarm activates 30 s after the entry time passed.
Instant: The alarm activates immediately.
4.2.n.5.2 Set retry
2 Set retry
>Off<
Set retry defines whether users can postpone or cancel an autoset. If this option
is set to On, you can postpone autoset during the Warning time (see "4.2.n.4.1
Warning time" on page 187). If the autoset has been postponed by a normal
user, the system will attempt autoset again after a time period defined in "8.4.8
AS user retry" on page 245.
Note:
The privileged users, Installer and Supervisor, can choose the postpone
time during the Warning time.
4.2.n.5.3 Silent autoset
3 Silent autoset
>Off<
If Silent autoset is on, the keypad buzzer remains silent during the "4.2.n.4.1
Warning time" described on page 187.
188