Interlogix ATSx500A Series Installation And Programming Manual page 218

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
To activate or deactivate shunting, toggle a local zone number.
See also "5.1.n.8 Shunt options" on page 201.
5.1.n.8.4 Indication
1>DOTL output
Not used
The menu allows you to assign door controller outputs for indication of the
specific access control events.
5.1.n.8.4.2 DOTL output
00>Not used
19 Output 17
Select an output on the door controller to indicate the Door Open Too Long
alarm.
5.1.n.8.4.3 Warning output
00>Not used
20 Output 17
Select an output on the door controller to indicate the warning before the shunt
time or extended shunt time expires. See also "5.1.n.8.2 Shunt timers" on page
202.
5.1.n.8.4.4 Forced door
00>Not used
19 Output 17
Select an output on the door controller to indicate that the door is forced (opened
without a successful authorization).
5.1.n.8.5 Until door CL
5 Until door CL
>No<
If set to Yes, the door shunt zones remain shunted as long as the door is
opened.
5.1.n.8.6 CancelAfterCL
6 CancelAfterCL
>No<
For security reasons, it may be required to limit the shunt period as much as
possible. If the option is set to Yes, the door shunt zones are shunted until the
door is closed. Opening the door again within the shunt time is not possible, as
this will generate an alarm (there is always a debounce time of approx.
2 seconds).
212
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual