Interlogix ATSx500A Series Installation And Programming Manual page 136

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
1.2.6 Test call opts
1>CS 1
2 CS 2
The Test call menu allows you to define the automatic test call interval, and to
perform a test call on demand.
1.2.6.n Select CS
1>Test call mode
Off
Select central station to configure test call options.
1.2.6.n.1 Test call mode
1 Test call mode
>Off<
Select test call mode. The following modes are available:
Off: Automatic test call functionality is disabled.
Time: Automatic test call triggers every day at the time of the day
programmed in "1.2.6.n.2 Test call time" below.
Period: Automatic test call triggers once at the time specified in "1.2.6.n.2
Test call time" below, and then repeats with the interval programmed in
"1.2.6.n.3 Period" on page 131.
1.2.6.n.2 Test call time
2 Test call time
>00:35<
If the "1.2.6.n.1 Test call mode" above is set to Time, the menu allows you to
define the time of the day for test calls to the central station.
If the "1.2.6.n.1 Test call mode" above is set to Period, the menu allows you to
define the time of the day for the first test call to the central station. Once the time
is defined in this menu, the panel starts sending the event RP (Automatic
test/ring-in test) report to the appropriate central stations. The event is sent
periodically, the period is defined in the menu "1.2.6.n.3 Period" on page 131.
Note:
If the option "1.2.6.n.4 Extend" on page 131 is set to Yes, the real time of
the test call can vary depending on other events reported to the central station.
This start time is used by the panel when one of the following occurs:
The panel is reset
One of the test call options is changed by installer
The test call time is set in 24 h format, as HH:MM.
130
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual

Hide quick links:

Advertisement

Table of Contents
loading