Sbsc Policy - Interlogix ATSx500A Series Installation And Programming Manual

Advisor advanced
Table of Contents

Advertisement

For SES Grade 3 is not allowed to program GPRS communication as primary
CS, it is only allowed in Grade 2.
The table below indicates the required polling intervals for SES Grade 2 and
Grade 3.
Back-up CS
(GPRS)
* 2, 3: EN-CH Grade of the system
The following options must be set:
Standard and
Required
category
polling
interval
SES CHD.07 (V3 / 01.01.2011)
AÜA-B25
25 h
AÜA-B5
5 h
AÜA-S180
180 s
AÜA-S20
20 s

SBSC policy

Larmklass 1
Required settings are all EN 50131 Grade 2 settings with the following
modifications:
4.2.n.5.1 Entry alarms: Instant
8.7.6.9 Reporting delayed: No
See also "EN 50131 Grade 2" on page 302.
Larmklass 2
Required settings are all EN 50131 Grade 3 settings with the following
modifications:
4.2.n.5.1 Entry alarms: Instant
8.7.6.9 Reporting delayed: No
See also "EN 50131 Grade 3" on page 303.
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Primary CS (IP)
AÜA-B25
25 h
AÜA-B25
25 h
2
AÜA-B5
5 h
2
Comm. path and
dialler
IP built-in, or GPRS
via ATS7310
IP built-in, or GPRS
via ATS7310
IP built-in, or GPRS
via ATS7310
IP built-in
Chapter 8: Regulations
AÜA-B5
AÜA-S180
5 h
180 sec
2, 3
2, 3
2, 3
2, 3
Option
9.1.n.8.3.2 Heartbeat time
9.1.n.8.3.2 Heartbeat time
9.1.n.8.3.2 Heartbeat time
9.1.n.8.3.2 Heartbeat time
AÜA-S20
20 sec
2, 3
2, 3
Required
value
24
4
00:02'30
00:00'10
309

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents