Interlogix ATSx500A Series Installation And Programming Manual page 260

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
After changing the scheme from classic to flexible, all programmed object
dependencies (for example, condition filters, cameras, etc.) will be
unavailable. The appropriate parameters will be set to "Not exist" instead of
previously programmed objects, until the scheme is changed back.
See also "Zone, output, and door addressing" on page 31 in Chapter 2
"Installation".
8.8 PA and other
1>Panic mode
Silent
The menu allows you to configure panic alarm mode, chime, and buzzer options,
etc.
8.8.1 Panic mode
1 Panic mode
>Silent<
Panic mode can be one of the following.
Silent: The panic alarm is silent (no siren activation)
Audible: The panic alarm is standard (with siren activation)
Audible alarm if line fault: The panic alarm is audible only if a Line Fault (LF)
or a Failed To Communicate (FTC) fault is present
8.8.2 Chime menu
1>Chime in PS
No
The Chime menu allows you to set up chime options.
8.8.2.1 Chime in part set
1 Chime in PS
>No<
The Chime in part set option defines whether the chime option is active when the
area is in the part set mode.
8.8.2.2 Latched chime
2 Latched chime
>Yes<
If the Latched chime option is set to Yes, disabling the chime only affects the
chime functionality until the next time the area is unset. Otherwise it should be
enabled manually.
254
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual