Interlogix ATSx500A Series Installation And Programming Manual page 164

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
2.2.2.n.4.8.0 Add macro
Access the Macro filter menu option to add a macro. If the macro is created
successfully, the following message appears:
INFO
Macro added
The new macro is given the default name "Macro N" and placed on the end of the
macro list. You can now start editing its details.
2.2.2.n.4.8.m Select macro
Select an existing macro to program.
2.2.2.n.4.8.m.1 Macro name
1 Macro name
>Macro 1
<
The name identifies the macro for installer, making the programming
dependencies clearer.
2.2.2.n.4.8.m.2 Formula
1>!Door Open.2
2 OR
The Formula menu allows definition of the macro formula. 4 events can be
combined in a formula.
2.2.2.n.4.8.m.2.x Select event
Select the appropriate event to configure it.
1>Group
Door
To choose an appropriate event, you must define the source of the event first.
The source is defined by a group of objects, and an object within this group.
Available groups are listed in Appendix A, "Advisor Advanced events", Table 32
on page 322.
When the group and the object (if available) are selected, select the appropriate
event. The available selection depends on the selected source. The full event list
with sources is shown in Appendix A "Advisor Advanced events", Table 32 on
page 322.
The following functions are available for the selected event:
1. Group: Select group
2. Input flag: Select an input flag from the group above
3. Item: Select an item for the Input flag above
4. Inversion: Invert the selected event. If inverted, it is marked with '!' in the
formula
158
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual

Hide quick links:

Advertisement

Table of Contents
loading