Interlogix ATSx500A Series Installation And Programming Manual page 152

Advisor advanced
Table of Contents

Advertisement

Chapter 5: Menu reference
Card or PIN: Either a PIN or a card is required to set or unset
2.2.1.n.3.7.2 Logoff time
2 Logoff time
>3<
A time period (in minutes) of the keypad inactivity before the user is automatically
logged off.
Allowed range is 1 to 255 minutes. Default value is 3.
2.2.1.n.3.7.3 1 x set/unset
3 1xset/unset
>Off<
One-time badge to set/unset defines if the selected keypad allows you to set or
unset areas with one badge. The following values are available:
Off: One badge does not cause any set or unset action.
Unset: One badge unsets areas.
Set-Unset: One badge sets or unsets areas.
Part set 1-unset / Part set 2-unset: One badge partially sets or unsets areas.
2.2.1.n.3.7.4 3 x badge set
4 3xbadge set
>Off<
Three-time badge to set defines if the selected keypad allows you to set areas
with triple badge. The following values are available:
Off: Triple badge does not cause any action.
Set: Triple badge sets areas.
Partset1 / Partset 2: Triple badge partially sets areas.
Notes
This functionality works only if areas can be set with a card. See
"2.2.1.n.3.7.1 Card&PIN mode" on page 145 for available modes.
This functionality is available only if the "2.2.1.n.3.7.3 1 x set/unset" option
described above is not configured as Set-Unset.
2.2.1.n.3.8 EE PIN lock
8 EE PIN lock
>No<
If the EE PIN lock option is set to Yes, it is not possible to use a PIN during the
entry time.
146
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual