5.1.n.6.4.2 RTE zone
0>Not used
19 Zone 19
Select a zone operating as an RTE input for an intelligent door.
Note:
It is not possible to choose a zone, which is already used in the door
controller (for example, DOTL or door zone, etc.)
See also "5.1.n.6.4 RTE options" on page 201.
5.1.n.6.4.3 Dis. when set
1>IN reader
2 OUT reader
Specify if the RTE functionality is disabled if any of door areas are set.
First, select the appropriate IN or OUT reader. Next, set Yes or No to configure
the option for the specified reader.
5.1.n.6.4.4 RTE Control
4 RTE Control
>Timed door OP<
Defines the operation of the Request To Exit button.
Timed door open. When the RTE button is pressed, the door unlocks for the
programmed unlock time. See "5.1.n.5.1 Unlock time" on page 198.
Hold door open. Allows the door to be held unlocked for as long as the RTE
button is pressed or for the programmed unlock time, whichever is longer.
Shunt only. When the RTE button is pressed, the zone is shunted, but no
access is granted.
5.1.n.6.5 Reporting
1>CL & Locked
No
Determines when access control events are reported.
5.1.n.6.5.1 CL & Locked
1 CL & Locked
>No<
If set to yes, the door is reported when closed and locked (lock command sent,
and zone status is normal).
Note:
There is no event specified in the control panel. This function can only be
used in conjunction with next options.
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Chapter 5: Menu reference
209