Appendix A: Advisor Advanced events
Group
Event
AREA
DSHUNTWARN
UNSETDELAYED
PROHIBITUNSET
ZNSHUNT
SHUNTFAULT
SENSRESET
SCH ACTIVE
Group
Event
Keypad
OFFLINE
RTE
CODETAMPER
TAMPER
DURESS
ACTIVE CARD
PIN
DOORACC
LOCKED
ISOLATED
CHIME
VALID CARD
EXIT STARTED
ENTRY STOPPED
UNKNOWN CARD
SCH ACTIVE
Group
Event
Expander
OFFLINE
MAINSFAULT
316
#
Event description
90
Door shunt warning A zone in the area is in shunt
91
Unset delayed
92
Prohibit unset
93
Zone shunted
94
Faulty zone
shunted
95
Sensor reset
96
Schedule active
#
Event description
1
Keypad is offline
2
RTE triggered
3
Code tamper
4
Keypad tamper
5
Duress code
6
Badged card
7
Valid PIN
8
Valid PIN or card
9
Keypad is locked
10
Keypad is isolated
11
Keypad chime
active
12
Valid card
13
Exit time started
14
Entry time stopped
15
Card is not
recognized
16
Schedule active
#
Event description
1
Expander is offline
2
Mains fail
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Notes
warning time
Area unset delayed
User unset prohibited
A zone in the area is shunted
A zone in the area is in the
shunt fault state
Notes
Active if a keypad is offline
Keypad RTE input triggered
Active when a keypad is locked
for 2 minutes due to 3 wrong
PIN entries
Keypad tamper
Duress code entered on this
keypad
A card is badged on this keypad,
active for 3 s
Valid PIN entered on this
keypad, active for 3 s
Valid PIN or card entered on this
keypad, active for 3 s
Code tamper. It restores after
the timeout has expired.
Valid card entered on this
keypad, active for 3 s
Exit time started during set from
the selected keypad
Entry time stopped during unset
from the selected keypad
Notes