19–2
Terminal C Terminal 50
AVENSIS REPAIR MANUAL (RM1018E)
STARTING & CHARGING
(d)
Do no–load performance test
(1)
Torque: 5.9 N m (60 kgf cm, 52 in lbf)
(2)
(3)
(4)
A82618
Specified current: 85 A or less at 11.5 V
2.
INSPECT STARTER RELAY ASSY
(a)
Continuity inspection.
(1)
Specified condition:
Terminal No.
1 – 2
3 – 5
B16200
http://vnx.su
STARTING SYSTEM (1ZZ–FE/3ZZ–FE)
Connect the field coil lead wire to terminal C. Make
sure that the lead is not grounded.
Clamp the starter in a vise.
Connect the battery and an ammeter to the starter
as shown in the illustration.
Check that the starter rotates smoothly and steadily
with the clutch pinion gear extended. Check that the
ammeter reads the specified current.
Using an ohmmeter, check for continuity between
each terminal.
Specified condition
(Apply battery voltage terminals 1 and 2)
Continuity
No continuIty
Continuity

Advertisement