Inscribed Mark
22.
INSPECT PRESSURE PORT UNION SUB–ASSY
(a)
If the union seat in the pressure port union sub–assy is remarkably damaged, it may cause fluid leak-
age. Replace the pressure port union sub–assy.
SST(s)
Oil Seal
Vinyl Tape
CE-122
AVENSIS REPAIR MANUAL (RM1018E)
POWER STEERING
If necessary, replace the flow control valve assy with the one
having the same letter as inscribed on the housing sub–assy
front.
HINT:
There are 6 different marks for flow control valve assy.
D31004
21.
(a)
If it is less than the minimum, replace the compression spring.
Vernier Calipers
R08702
23.
(a)
(b)
NOTICE:
Make sure that the oil seal is installed facing in the correct
direction.
F08480
24.
(a)
(b)
NOTICE:
Do not damage the oil seal lip.
HINT:
Tape the shaft before inserting.
D30334
http://vnx.su
–
VANE PUMP ASSY (AZ Series)
Inscribed mark: A, B, C, D, E or F
Mark
A
B
C
D
E
F
INSPECT FLOW CONTROL VALVE COMPRESSION
SPRING
Using vernier calipers, measure the free length of the
compression spring.
Minimum free length: 36.9 mm ( 1.453 in.)
INSTALL VANE PUMP HOUSING OIL SEAL
Coat a new housing oil seal lip with power steering fluid.
Using SST(s) and a press, install a new housing oil seal.
SST
09950–60010 (09951–00280), 09950–70010
(09951–07100)
INSTALL W/PULLEY SHAFT SUB–ASSY
Coat inside bushing surface of the housing sub–assy
front with power steering fluid.
Gradually insert the w/pulley shaft sub–assy.
51–13
Part number
44330–05130
44330–05140
44330–05150
44330–05160
44330–05170
44330–05180