ORIGINAL SIZE DETECTION

4.3 ORIGINAL SIZE DETECTION

4.3.1 BASIC MECHANISM

&
%
$
"
[B] B5
[C] LG
[A]
B597D110.WMF
The original size is detected by four original width sensors [A] and two original
length sensors, [B] and [C].
The machine determines the original width when the leading edge of the original
activates the registration sensor.
The ARDF detects the original size by combining the readings of the four width
sensors and two length sensors, as shown in the table on the next page.