Gestetner B147 Service Manual page 233

Table of Contents

Advertisement

SC No.
Item
SC 640
BCU -
The check sum of the interface
Controller
between the BCU and
communication
controller is not the same.
error (check
sum error)
SC 641
BCU –
The controller does not receive
Controller
any response from the BCU
communication
three consecutive times when
error (no
sending a signal every 100ms.
response)
SC 670
No response
When the main power is
from BCU at
turned on or the machine
power on
starts warming up from
energy-saving mode, the
controller does not receive a
command signal from the
BCU.
SM
Definition
Possible Cause
• Defective controller
• Defective BCU
• Loose connection
• Defective controller
• Defective BCU
• Loose connection
• Defective controller
• Defective BCU
Related
Troubleshooting Procedure
SCs
1. Turn the main switch off and on.
2. Replace the controller.
3. Replace the BCU.
1. Turn the main switch off and on.
2. Check the connection between the
BCU and controller.
3. Replace the controller.
4. Replace the BCU.
1. Turn the main switch off and on.
2. Check the connection between the
BCU and controller.
3. Replace the controller.
4. Replace the BCU.
4-31
SC TABLE
Type
CTL
CTL
CTL
B147/B149/B190

Advertisement

Table of Contents
loading

This manual is also suitable for:

B149B190

Table of Contents