SC TABLE
SC No.
Item
SC 240
LD over
The power supply for the LD
240-001: Y
unit exceeds 67 mA.
240-002: M
240-003: C
240-004: K
SC 260
LD HP sensor
During homing, it takes more
not switched on
than five seconds to switch the
(for K only)
HP sensor on (the sensor
actuator does not cover the
sensor).
SC 261
LD HP sensor
After the laser beam pitch was
not switched off
changed, it takes more than
(for K only)
five seconds for the HP sensor
to switch off.
B147/B149/B190
Definition
Possible Cause
• LD worn out
(current/light output
characteristics have
changed.)
• LD broken (short
circuit)
• Defective motor
• Defective sensor
• Mechanical problem
when switching the
actuator
• Brown fuse (FU81) on
the Power supply unit
• Defective motor
• Defective sensor
• Mechanical problem
when switching the
actuator
• Brown fuse (FU81) on
the Power supply unit
Related
Troubleshooting Procedure
SCs
1. Turn the main switch off and on.
2. Replace the laser optics housing unit.
1. Turn the main switch off and on.
2. Check the sensor actuator position of
the LD positioning motor.
3. Replace the LD positioning motor.
4. Replace the LD home position
sensor.
5. Check and/or replace the PSU.
1. Turn the main switch off and on.
2. Check the sensor actuator position of
the LD positioning motor.
3. Replace the LD positioning motor.
4. Replace the LD home position
sensor.
5. Check and/or replace the PSU.
4-18